Pellet stoves Installation and use manual
Information Wood pellets are manufactured by hot-extruding compressed sawdust which is produced during the working of natural drie
Technical characteristics 1.7 Vega d.50 d.80 154 154 162 325 172 1000 530 470 Astra d.50 d.80 325 154 162 172 1010 570 520 154 10
Aurora d.50 d.80 154 154 162 325 172 1010 570 520 Technical characteristics Antares 540 570 1160 d.50 d.80 366 214 162 204 204 11
Technical characteristics Technical characteristics Vega - Astra - Aurora Antares Overall thermal power ITALY 8.5 KW / 7310 kcal 9.9KW / 8500 kcal
Installation 2.1 Working environment For proper functioning and a good temperature distribution, the stove should be positioned in a location where it
Installation 2.2 Preparation The Vega stove is delivered in a single package. Astra, Aurora, and Antares stoves are delivered in two packages: The f
Installation 2.3 Installation and fitting Installation and assembly of the stove must be carried out by a qualified engineer. The stove must be insta
Installation When making the hole for the passage of the smoke discharge pipe, it is necessary to take into account the possible presence of flammable
Installation Lining up the smoke outlet and the connecting pipe If the stove needs to be connected to a discharge pipe which goes through the rear wal
Installation 2.6 Connection to an external fluepipe in insulated or double-walled pipe The external fluepipe must have internal dimensions of minimu
Contents 2.1 Working environment 2.2 Preparation 2.3 Installation and fitting 2.4 Connection to the external air intake 2.5 Connection to the flue
Installation 2.8 Operating problems caused by draught defects in the flue Example 1: 8 m/sec wind blowing downwards at 45° Example 2: 8 m/sec wind blo
2.9 Fitting the ceramic cladding on Astra-Aurora-Antares ORIENTATION OF THE CERAMICS After positioning the stove in the chosen location, level up the
FITTING THE CERAMIC CLADDING After reading the previous paragraph entitled "Orientation of the ceramics", scrupulously follow the stages de
Installation of steatite cladding Always start laying the plates starting from the lower ones. Orienting it as shown in the diagram below, insert a pl
VARIATION FOR ANTARES Remove the two screws from the pellet compartment cover, take it off and position the ceramic top (fig. 13). Refit the cover an
Use of the stove 3.1 Checks to make before lighting the stove Check that all the safety conditions described above have been met. Make
3.3 Instructions and advice on first lighting Use of the stove Avoid touching the stove during the initial lighting, since the paint is hardening at
Use of the stove 3.4 Control panel Let us get to know the functions of the control panel. The control panel replicates perfectly the functions of the
Use of the stove 3.5 Managing the stove with the LCD To use the remote control for purposes of programming or operation, take up a position within the
Use of the stove 3.6 Settings to carry out before first lighting Set the main switch on the rear of the stove to position (1). The disp
Chapter 4 Maintenance 4.1 Periodical cleaning and checks 4.2 Cleaning the glass 4.3 Monthly check 4.4 Check to be carried out every 2 or 3 mo
Use of the stove Procedure for recipe selection Requirements: • Scales (measuring up to 4 kg) with graduations down to 10 g • MCZ pellet measuring
Use of the stove 3.10 HOW TO DISPLAY AND PROGRAM THE SELECTED RECIPE Press keys 3 and 4 simultaneously. The display shows the recipe c
Use of the stove 3.11 Lighting the stove using the control panel or the remote To start the stove, press Key 5 for several seconds. After a few moment
Use of the stove 3.12 Automatic operation with the digital room thermostat It is possible to regulate the power of the stove automatica
Use of the stove 3.15 Automatic operation with the timer-thermostat The timer-thermostat function is used to program the automatic lighting and shutdo
Use of the stove 3.16 Programming the timer-thermostat SELECTION OF THE CURRENT TIME AND DAY OF THE WEEK If the setting of the current
Use of the stove Code Message on display Function Key sequence UT 01 OFF Activating timer; use Keys 1 and 2 to change the current day To move on
Use of the stove 3.17 Operation of the stove using the external thermostat The stove can also be controlled as regards temperature by a
Use of the stove 3.19 Watching the flame In order to achieve good running for the stove, you need to know how to "read" the flame. The chara
Use of the stove 3.20 Alarm signals In the event that a running problem occurs, as the stove is equipped with a computerised monitoring
3 Preface Dear Customer, We would like to thank you for the preference which you have decided to bestow on MCZ products, and particularly for ch
Use of the stove 3.21 Other messages “COOL FIRE” Generally appears at the cooling stage following a shutdown caused by an electrical power-cut. “MODU
The stove can be shut down at any time and in whatever state it is in. Never shut the stove down by cutting off the electricity supply: Always leave
Maintenance 4.1 Periodical cleaning and checks ATTENTION ! All operations of cleaning all parts must be carried out with the stove completely cold an
Maintenance Cleaning to be dealt with by specialized technicia Still with the stove cold, open the door below the grate (Fig. 31) and with a vacuum cl
Maintenance At the end of season, before placing the stove in storage, we recommend completely removing pellets from the hopper with the use of a vacu
Maintenance 4.9 Checking the internal components Checking the internal electromechanical components must only be done by qualified personnel with tech
Electrical system 5.1 Electrical / functional diagram Programming / external room thermostat 45
Electrical system ATTENTION ! This operation must be carried out exclusively by a specialised technician, with the stove completely cold and the el
ATTENTION: All repairs must be carried out exclusively by a specialised technician, with the stove completely cold and the electric plug pulled out.
PROBLEM POSSIBLE CAUSE REMEDY The smoke extraction motor does not work. 1. No electrical supply to the stove. 1. The motor is br
MCZ guarantees the stove, excluding the components listed below which are subject to normal wear and tear, for a period of two years from the date of
Pipe bracket Ø 8 cm code120144 Windproof cowl Ø 8 cm code160156 Gasket code120194 Wall flange Ø 8cm code160157 Tee Ø 8cm code160089 Bend 45° Ø 8cm cod
Touchup paint BLACK code180042 Glass cleaning spray code180012 Bag of pellets code160159 External thermostat code160265 Floor protection plate in ste
Main board Astra-Aurora-Vega-Antares code160238 Smoke fan code160234 Command panel code160242 Remote control LCD code160245 Exchanger board silenced c
Supply cable code160246 Main switch code160193 Pressure switch code160230 Ignition sparkplug code120660 Reduction motor code160233 Smoke sensor code16
Remote control glass code160264 Expansion module IR Antares code160261 Serial connector for thermostat code160262 Expansion module IR A-A-V code160263
8-Spare parts for pellet stoves 3 4 2 8 6 7 1 5 54
Ceramics for Astra stove Ceramics for Aurora stove Ceramics for Vega stove Ceramics for Antares stove 10 11 14 13 12 15 12 16 17 18 55
POSITION CODE DESCRIPTION PCS 1 120104 L=2mt Door gasket ASTRA-AURORA-ANTARES-VEGA 1 2 170158 Glass ASTRA-AURORA-VEGA 1 2 170154 Glass ANTARE
Date Installer Parameter No. Technical menu Recipe Was Become
58 10-Summary of main instructions and operating rules Fuel type: 6 mm diameter pellets, tested according to ONORM M 7135. The stove must be installed
Installation of the stove, making the electrical connections, checking its operation, and maintenance are all tasks which should be carried out by q
59 Notes
Code 89030367 Rev.10/2004 Printed MCZ Spa via Oberdan,86 33070 Vigonovo di Fontanafredda (PN) Italy Telefono: 0434/599599 r.a. Fax:
Information 1.3 Operating instructions In case of any problems, get in touch with your dealer, or a qualified engineer authorised by MCZ, and if a re
1.4 Safety devices Information The stove is fitted with the following safety devices: PRESSURE SWITCH Monitors pressure in the smoke duct. It is desi
1.5 Operating principle The pellets are picked up from the hopper on board the stove and transported by a feed screw. They are then introduced into t
Commenti su questo manuale